• Skip to primary navigation
  • Skip to main content
  • Skip to footer
  • Magyarország
    • | RBS Group
    • | Austria
    • | Belgium
    • | Bulgaria
    • | Croatia
    • | Czech Republic
    • | France
    • | Germany
    • | Greece
    • | Hungary
    • | Italy
    • | Poland
    • | Serbia
    • | Slovakia
    • | Slovenia
    • | Spain
    • | Switzerland
    • | The Netherlands
    • | Turkey
    • | United Kingdom
  • en
    • Magyar (Hungarian)
    • English
RBS - HU
  • Applications
    FLAT ROOF
    • Inverted roof
    • Roof terrace
    • Greenroof
    • Parking roofs
    • Duo roof/plus roof
    • Thermal insulation of industrial flat roof
    FLOOR
    • Residential floor
    • Industrial floors
    • Cold storage floors
    WALL
    • Thermal bridges
    • Socle insulation
    • Inside wall insulation
    • Core insulation
    • External thermal insulation system
    PERIMETER / BASEMENT
    • Perimeter
    • Base-slab insulation
    • Basement insulation
    PITCHED ROOF
    • Pitched roofs thermal insulation above rafters
    • Pitched roofs thermal insulation below rafters
    • Reinforced concrete pitched roofs
    • Insulation of poultry sheds
    SPECIAL APPLICATIONS
    • Renovation
    • Sport surfaces
    • Unheated structures
    • Pipework systems
    • Lightweight fill
    • Roads, railway tracks
  • Products
    RAVATHERM XPS 250 PB RAVATHERM XPS 300 SL RAVATHERM XPS 300 ST RAVATHERM XPS 300 WB RAVATHERM XPS 500 SL RAVATHERM XPS 700 SL RAVATHERM SW Roof RAVATHERM SW ETICS Plus
  • Knowledge Base
  • Downloads
  • About Us
    • About Us
    • History of XPS
    • Image video
    • News
    • References
  • Contact
    • Contact
    • Find your dealer
Search
Results for {phrase} ({results_count} of {results_count_total})
Displaying {results_count} results of {results_count_total}

Próbáld ezt: XPS hőszigetelésKőzetgyapot hőszigetelésGyakori kérdések

  • Applications
  • Knowledge Base
  • Downloads
  • Products
    • RAVATHERM XPS 300 SL
    • RAVATHERM XPS 300 WB
    • RAVATHERM XPS 300 ST
    • RAVATHERM XPS 500 SL
    • RAVATHERM XPS 700 SL
  • About us
  • Contact
    • Find your dealer
    • Contact
huen
Choose country

Roof terrace

  • Recommended products
  • Implementation recommendations
  • References
  • Downloads
  • Design guidelines
Home / Alkalmazások / Roof terrace
  • Recommended products
  • Implementation recommendations
  • References
  • Downloads
  • Design guidelines

Írjon nekünk!
Message can not be empty!

Írjon nekünk!

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
PP*

General information

Terrace roofs are walkable flat roofs which ensure utilisation for various functions on the top slab of the building. In each case, a covering with a screed depending on the nature of the covering is laid which correctly serves the purpose of utilisation.
These areas are usually suitable for recreational purposes, designed with walkable cladding and possibly with vegetation and shading structures.

Recommended Products

RAVATHERM XPS

RAVATHERM XPS 300 SL

RAVATHERM XPS 300 SL

The RAVATHERM XPS 300 SL thermal insulation is manufactured using an extrusion production process, which results in a…
Read More
RAVATHERM XPS 500 SL

RAVATHERM XPS 500 SL

Heat and sound insulation of a flat roof - Thermal insulation of single-layer, inverted layered flat roofs, non-walkable flat…
Read More

Other information

Flat roofs with inverted order of layers are especially suitable for creating utilised flat roofs and terrace roofs. The thermal insulation provides mechanical protection for the waterproofing membrane not only during the construction work but also in the course of intensive use.

The excellent features of closed-cell polystyrene surpass several technical characteristics of the materials (the wide spread EPS or mineral wool thermal insulation) of straight order (slab – thermal insulation – waterproofing) flat roofs by an order of magnitude. Such characteristics are for example compressive strength, tensile strength perpendicular to the surface, water uptake features, vapour technology advantages.

During the manufacturing of extruded polystyrene (XPS), the extrusion production process results in a homogeneous, closed-cell material structure with a smooth surface crust (called extrusion crust) which provides a number of favourable material characteristics:

  • persistently high thermal insulation level,
  • water and frost resistance,
  • high strength,
  • high flexible rigidity,
  • high resistance to vapour diffusion.

All these favourable characteristics make the XPS thermal insulation material suitable for, among others, the excellent realisation of terrace roofs.

In the construction of a roof terrace, the inverted order of layers and the special strength of RAVATHERM XPS used as thermal insulation ensure special flexibility and freedom for the designer. Walkable and green surfaces, heavy flower boxes, legs of shades, bases of railings or street furniture can be easily installed anywhere without breaking the waterproofing membrane and creating thermal bridges. Later on, during transformations of the building, the roof terrace may be rearranged so that work does not endanger the operational safety of the building, that is, the waterproofing layer will not have to be broken in the course of work.

Technical

ROOF TERRACE CLADDING

The cladding of terrace roofs may be made with frost-resistant tiles glued on the entire surface, with cladding bed without adhesive or pads to be placed under.
To avoid damages arising from thermal expansion and frost, for dismountable cladding (for example concrete tiles with surface treatment, WPC or wood), it is expedient to use self-supporting cladding tiles with a bedding layer without adhesive (basalt chippings), laid on premanufactured supporting pads.

In general, the walking surface of terraces is made with,

  • concrete tiles laid in a 3 to 5 cm thick layer of 4/8 mm chippings
  • concrete tiles laid on special plastic supporting plates
  • concrete paving blocks embedded in a 5 to 8 cm thick, 4/8 mm chippings bed

laid on a vapour-permeable, non-absorbent, rotproof separation layer (polypropylene geotextile) placed onto the RAVATHERM XPS thermal insulation.
In the case of tile cladding laid on supporting plates, even positioning of the thermal insulation boards should be ensured, so a leveling layer may be needed between the overlaps of the waterproofing layer if multilayer bituminous insulation is used.

If glued tiling is required with closed gaps, the frost-resistant tiles have to be fixed to the min. 6-cm thick reinforced, frost-resistant concrete screed created on top of a min 4-cm thick, 4/8 mm chippings bed, by interposing a vapour-permeable separation layer,
using frost resistant adhesive.

Separation layers have been inserted into the structural order as a result of several decades of experience gained in refurbishing roof terraces. This considerably reduces damages caused by thermal expansion movements. The cladding and its bedding, as well as the thermal insulation and the supporting structure will be able to move independently. Great care must be taken to ensure frost-resistance of the cladding, its bedding and the adhesive as well as to that of the sloping concrete or screed on top of the waterproofing layer.

WATER DRAINAGE OF ROOF TERRACES

The efficient and quick removal of water must be resolved also on roof terraces. Water needs to be drained from the surface of both the cladding and the waterproofing membrane, and safety overflow must also be taken care of. The slope and drainage of the waterproofing membrane has to be realised always in consideration of professional guidelines. The sloping of the cladding may be different from that. The easiest way to realise this slope compensation is by laying down a chippings bed.

References

Related References
RAVATHERM XPS in the mouth of Castle Hill
Grand Hotel Esztergom
RAVATHERM XPS at the top of Tüskecsarnok

ÉNGY, TERC code

  • Thermal insulation of inverted flat roofs (utilized) 48-007-11.22.1
    PRODUCT NAMETHICKNESSÉNGY CODE (MV)TERC CODE
    RAVATHERM XPS 300SL3048-007-055927348-007-21.1.1.7.3-0110112
    RAVATHERM XPS 300SL4048-007-055928548-007-21.1.1.7.3-0110113
    RAVATHERM XPS 300SL5048-007-055929048-007-21.1.1.7.3-0110114
    RAVATHERM XPS 300SL6048-007-055930048-007-21.1.1.7.3-0110115
    RAVATHERM XPS 300SL8048-007-055931248-007-21.1.1.7.3-0110116
    RAVATHERM XPS 300SL10048-007-055932448-007-21.1.1.7.3-0110117
    RAVATHERM XPS 300SL12048-007-055933648-007-21.1.1.7.3-0110118
    RAVATHERM XPS 300SL14048-007-055934148-007-21.1.1.7.3-0110119
    RAVATHERM XPS 300SL15048-007-242916648-007-21.1.1.7.3-0110120
    RAVATHERM XPS 300SL16048-007-242917148-007-21.1.1.7.3-0110121
    RAVATHERM XPS 300SL18048-007-242918348-007-21.1.1.7.3-0110122
    RAVATHERM XPS 300SL20048-007-242919548-007-21.1.1.7.3-0110123
    RAVATHERM XPS 300SL22048-007-438508048-007-21.1.1.7.3-0110103
    RAVATHERM XPS 300SL24048-007-438509248-007-21.1.1.7.3-0110104
    RAVATHERM XPS 300SL26048-007-438510248-007-21.1.1.7.3-0110106
    RAVATHERM XPS 300SL28048-007-438511448-007-21.1.1.7.3-0110107

Tender text

  • Thermal insulation of inverted flat roofs with concrete paving (utilized)
    - 300 SL

    Hőszigetelés elhelyezése fordított rétegrendű, kiselemes járólappal fedett járható lapostetőben sima
    felületű RAVATHERM XPS 300 SL extrudált polisztirolhab lemezzel,

    30-40 mm: λD=0,033 W/mK,
    XPS – EN13164 – T1 – CS(10\Y)300 – CC(2/1,5/50)130 – DS(70,90) – DLT(2)5 -WD(V)3 – WL(T)0,7 – FTCD1
    50-60 mm: λD=0,034 W/mK,
    XPS – EN13164 – T1 – CS(10\Y)300 – CC(2/1,5/50)130 – DS(70,90) – DLT(2)5 -WD(V)2 – WL(T)0,7 – FTCD1
    80 mm: λD=0,033 W/mK,
    XPS – EN13164 – T1 – CS(10\Y)300 – CC(2/1,5/50)130 – DS(70,90) – DLT(2)5 -WD(V)1 – WL(T)0,7 – FTCD1
    100-120 mm: λD=0,034 W/mK
    XPS – EN13164 – T1 – CS(10\Y)300 – CC(2/1,5/50)130 – DS(70,90) – DLT(2)5 -WD(V)1 – WL(T)0,7 – FTCD1
    140-280 mm: λD=0,035 W/mK
    XPS – EN13164 – T1 – CS(10\Y)300 – CC(2/1,5/50)130 – DS(70,90) – DLT(2)5 -WD(V)1 – WL(T)0,7 – FTCD1

    A vízszigetelés, szűrő-elválasztó réteg, a burkolati elemek és a bazaltzúzalék ágyazó réteg/távtartó
    lábak külön tételben kerülnek kiírásra.

Downloads

Related Downloads

Footer Newsletter

Do you want to be informed about our latest news?

E-mail address fault

NEWSLETTER (EN)

  • This field is for validation purposes and should be left unchanged.
  • Confirm Humanity - Before we subscribe you, we need to confirm you are a human.

About Us

  • Ravago Building Solutions
  • About Us
    • Image video
    • News
    • References

Products

  • RAVATHERM XPS 300 WB
  • RAVATHERM XPS 300 SL
  • RAVATHERM XPS 300 ST
  • RAVATHERM XPS 500 SL
  • RAVATHERM XPS 700 SL

Applications

  • Applications

Knowledge Base

  • Knowledge Base

Downloads

  • Downloads

Contacts

  • Find your dealer
  • Find your dealer

Ravago Building Solutions
Hungary Kft.

8184 Balatonfűzfő, Almádi út 4.
[+36 88] 59 6979
info@ravatherm.com

Member of

Ravago

Kövess minket

™ Trademark of Ravago S.A.
  • Privacy Policy
  • Cookie Policy
  • Terms of Use
Results for {phrase} ({results_count} of {results_count_total})
Displaying {results_count} results of {results_count_total}

Próbáld ezt: XPS hőszigetelésKőzetgyapot hőszigetelésGyakori kérdések