• Skip to primary navigation
  • Skip to main content
  • Skip to footer
  • Magyarország
    • | RBS Group
    • | Austria
    • | Belgium
    • | Bulgaria
    • | Croatia
    • | Czech Republic
    • | France
    • | Germany
    • | Greece
    • | Hungary
    • | Italy
    • | Poland
    • | Serbia
    • | Slovakia
    • | Slovenia
    • | Spain
    • | Switzerland
    • | The Netherlands
    • | Turkey
    • | United Kingdom
  • en
    • Magyar (Hungarian)
    • English
RBS - HU
  • Applications
    FLAT ROOF
    • Inverted roof
    • Roof terrace
    • Greenroof
    • Parking roofs
    • Duo roof/plus roof
    • Thermal insulation of industrial flat roof
    FLOOR
    • Residential floor
    • Industrial floors
    • Cold storage floors
    WALL
    • Thermal bridges
    • Socle insulation
    • Inside wall insulation
    • Core insulation
    • External thermal insulation system
    PERIMETER / BASEMENT
    • Perimeter
    • Base-slab insulation
    • Basement insulation
    PITCHED ROOF
    • Pitched roofs thermal insulation above rafters
    • Pitched roofs thermal insulation below rafters
    • Reinforced concrete pitched roofs
    • Insulation of poultry sheds
    SPECIAL APPLICATIONS
    • Renovation
    • Sport surfaces
    • Unheated structures
    • Pipework systems
    • Lightweight fill
    • Roads, railway tracks
  • Products
    RAVATHERM XPS 250 PB RAVATHERM XPS 300 SL RAVATHERM XPS 300 ST RAVATHERM XPS 300 WB RAVATHERM XPS 500 SL RAVATHERM XPS 700 SL RAVATHERM SW Roof RAVATHERM SW ETICS Plus
  • Knowledge Base
  • Downloads
  • About Us
    • About Us
    • History of XPS
    • Image video
    • News
    • References
  • Contact
    • Contact
    • Find your dealer
Search
Results for {phrase} ({results_count} of {results_count_total})
Displaying {results_count} results of {results_count_total}

Próbáld ezt: XPS hőszigetelésKőzetgyapot hőszigetelésGyakori kérdések

  • Applications
  • Knowledge Base
  • Downloads
  • Products
    • RAVATHERM XPS 300 SL
    • RAVATHERM XPS 300 WB
    • RAVATHERM XPS 300 ST
    • RAVATHERM XPS 500 SL
    • RAVATHERM XPS 700 SL
  • About us
  • Contact
    • Find your dealer
    • Contact
huen
Choose country

Inside wall insulation

  • Recommended products
  • Implementation recommendations
  • References
  • Downloads
  • Design guidelines
Home / Alkalmazások / Inside wall insulation
  • Recommended products
  • Implementation recommendations
  • References
  • Downloads
  • Design guidelines

Írjon nekünk!
Message can not be empty!

Írjon nekünk!

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
PP*

General information

In cases where external insulation of the facade wall is not possible (e.g. existing buildings with protected facade view or historic building, walls in direct contact with the ground etc.), the RAVATHERM™ XPS 300 WB closed-cell insulation can be placed on the internal walls as well.
As the insulation is applied on the warm, inner side, the wall structure will be exposed to more severe temperature changes arising from winter/summer temperature changes.
Because of the above reasons, the installation of max. 3 to 4 cm closed-cell polystyrene foam thermal insulation is recommended.
Special attention should be paid also to thermal bridges along the adjoining structures (internal walls, floors, and slabs). The condensation risk must be checked carefully with respect to vapour migration in the entire order of layers considering the higher vapour load of rooms with high relative air humidity.

Recommended Products

RAVATHERM XPS

RAVATHERM XPS 250 PB

RAVATHERM XPS 250 PB

External wall thermal insulation on the basement wall, glued (fixing in a separate item) with extruded polystyrene foam sheet
Read More
RAVATHERM XPS 300 WB

RAVATHERM XPS 300 WB

Heat and/or sound insulation of a facade wall on a masonry or monolithic reinforced concrete structure, on a vertical surface,…
Read More

RAVATHERM SW

Other information

IMPROVING COMFORT CONDITIONS

The greatest advantage of inner-side thermal insulation is much higher comfort in the room after installation. The surface temperature of thermally insulated walls can increase even by several centigrades providing a pleasant thermal comfort for those in the room.

DECREASED MOLD-FORMATION RISK

The increase of the surface temperature involves the decrease of the risk of condensation. If there is no condensation and relative humidity on the internal surface of the wall does not reach 75% persistently, the likelihood of mold-growth will also decrease making the room healthier.

Regular ventilation is important even in internally insulated rooms, because only a little part of the vapour leaves through the boundary surfaces.
The rough, well-adhering surface of RAVATHERM™ XPS 300 WB boards creates a suitable basis for plastered or adhesive-bonded internal finishes (gypsum board, ceramic tiles etc.).

IF IT IS IMPOSSIBLE FROM THE OUTSIDE

When existing buildings are refurbished, it is not always possible to install thermal insulation on the external plane of the façade, especially when the original façade or its nature needs to be preserved.
For the subsequent thermal insulation of basement perimeter walls, application on the inner side is often the only possibility to improve thermal protection.

TEMPORARILY USED BUILDINGS

In the case of buildings or premises that are used only temporarily and not heated permanently, there are practical advantages of thermal insulation on the inner side, since there is no need to heat up the wall and slab structures with high heat storage capacity. In this way, the room can be heated up faster and using less energy.

Technical

CONSULT AN EXPERT

For designing thermal insulation for the inner side of an elevation wall, accurate knowledge of the existing uninsulated wall structure is a must. Thermal insulation will be installed on the internal side of the wall structure, so the winter temperature of the wall which is insulated from heated spaces and exposed to the temperature variations of the outside space will decrease as compared to the uninsulated status, and there is a higher risk of possible freezing. This is why inner-side thermal insulation can be applied in the case of walling made of frost-resistant materials in the entire cross-section.

VAPOUR CONTROL, VENTILATION

In most inner-side thermal insulation solutions, the design of internal vapour control, professional installation and the protection of vapour control layer(s) in case of building operation is inevitable. Thanks to the high vapour diffusion resistance of RAVATHERMTM XPS 300 WB, the thermal insulation can be used without a separate vapour barrier layer. If the thermal insulation is installed with close connection, with a closed gap, the risk of condensation and mold-growing behind the thermal insulation will remain low.

THERMAL INSULATION TURNED OVER

In order to prevent the “migration” of the condensation zone from the corner to the ceiling or floor, thermal bridge effects need to be reduced and the thermal insulation should be turned over also to the adjoining structures (ceiling, partition etc.) in a 30 to 50 cm width where necessary.
In consideration of the above, the RAVATHERM XPS thermal insulation boards provide a durable and efficient solution also as the inner-side thermal insulation of walls.

Tender text

  • Facade thermal insulation – thermal insulation on the inner side

    Hőszigetelés elhelyezése homlokzati fal belső oldalán ragasztva, érdesített felületű („nápolyimintás”) RAVATHERM XPS 300WB extrudált polisztirolhab lemezzel,

    30-50 mm-ig: λD=0,033 W/mK, EN13164 : T3 – CS(10\Y)300 – DS(70,90) – WL(T)0.7 – TR400

    A ragasztóanyag, a dübelek, a felületképzéshez szükséges vakolat, valamint a párazáró fólia külön
    tételben kerülnek kiírásra.

Downloads

Related Downloads
  • 02. Termékismertetők | RAVATHERM XPS

Footer Newsletter

Do you want to be informed about our latest news?

E-mail address fault

NEWSLETTER (EN)

  • This field is for validation purposes and should be left unchanged.
  • Confirm Humanity - Before we subscribe you, we need to confirm you are a human.

About Us

  • Ravago Building Solutions
  • About Us
    • Image video
    • News
    • References

Products

  • RAVATHERM XPS 300 WB
  • RAVATHERM XPS 300 SL
  • RAVATHERM XPS 300 ST
  • RAVATHERM XPS 500 SL
  • RAVATHERM XPS 700 SL

Applications

  • Applications

Knowledge Base

  • Knowledge Base

Downloads

  • Downloads

Contacts

  • Find your dealer
  • Find your dealer

Ravago Building Solutions
Hungary Kft.

8184 Balatonfűzfő, Almádi út 4.
[+36 88] 59 6979
info@ravatherm.com

Member of

Ravago

Kövess minket

™ Trademark of Ravago S.A.
  • Privacy Policy
  • Cookie Policy
  • Terms of Use
Results for {phrase} ({results_count} of {results_count_total})
Displaying {results_count} results of {results_count_total}

Próbáld ezt: XPS hőszigetelésKőzetgyapot hőszigetelésGyakori kérdések